Is there PFAS in Collegeville Trappe Joint Pwd tap water?

Yes, and above the federal limit. The highest PFOA or PFOS reading was 235 parts per trillion, against a limit of 4.

Collegeville Trappe Joint Pwd is a public water system in Pennsylvania, serving 10,000 people or fewer. The EPA required almost every system in the country to test for 29 PFAS compounds and published every result. These are that system’s own readings, not an estimate and not ours.

Every compound tested, 8 of 29 found

CompoundHighest readingFederal limitDetected in
PFOA235 ppt4 ppt13 of 13 samples
PFBS15.3 pptno federal limit13 of 13 samples
PFOS15 ppt4 ppt13 of 13 samples
PFHxA10.9 pptno federal limit13 of 13 samples
PFPeA8.4 pptno federal limit13 of 13 samples
PFBA6.6 pptno federal limit5 of 13 samples
PFHpA6.2 pptno federal limit10 of 13 samples
PFHxS4.2 ppt10 pptEPA has proposed withdrawing this limit3 of 13 samples
11Cl-PF3OUdSnot detectedno federal limit0 of 13 samples
4:2 FTSnot detectedno federal limit0 of 13 samples
6:2 FTSnot detectedno federal limit0 of 13 samples
8:2 FTSnot detectedno federal limit0 of 13 samples
9Cl-PF3ONSnot detectedno federal limit0 of 13 samples
ADONAnot detectedno federal limit0 of 13 samples
HFPO-DAnot detected10 pptEPA has proposed withdrawing this limit0 of 13 samples
NEtFOSAAnot detectedno federal limit0 of 13 samples
NFDHAnot detectedno federal limit0 of 13 samples
NMeFOSAAnot detectedno federal limit0 of 13 samples
PFDAnot detectedno federal limit0 of 13 samples
PFDoAnot detectedno federal limit0 of 13 samples
PFEESAnot detectedno federal limit0 of 13 samples
PFHpSnot detectedno federal limit0 of 13 samples
PFMBAnot detectedno federal limit0 of 13 samples
PFMPAnot detectedno federal limit0 of 13 samples
PFNAnot detected10 pptEPA has proposed withdrawing this limit0 of 13 samples
PFPeSnot detectedno federal limit0 of 13 samples
PFTAnot detectedno federal limit0 of 13 samples
PFTrDAnot detectedno federal limit0 of 13 samples
PFUnAnot detectedno federal limit0 of 13 samples

Every row is a compound the EPA required this system to test for, whether it was found or not. Readings are the highest single result the system reported. Compliance is judged on an annual average, so one high sample is not by itself a violation. “Not detected” means below the level the laboratory method can measure, which is not the same as zero. Last sample 9/20/2023.

What actually removes it

Boiling does not remove PFAS and concentrates it. Reverse osmosis and certified activated carbon do. These are the highest-graded filters in our database, scored 0 to 100 on the chemistry of the filter itself.